MULTIFERROIC MICRO-ELECTROMECHANICAL SYSTEMS FOR MAGNETIC SENSING AND WIRELESS POWER TRANSFER IN BIOMEDICAL APPLICATIONS

Loading...
Thumbnail Image
Degree type
Doctor of Philosophy (PhD)
Graduate group
Electrical and Systems Engineering
Discipline
Electrical Engineering
Subject
Magnetostrictive
MEMS
Multiferroics
Piezoelectric
RF MEMS
Wireless Power Transfer
Funder
Grant number
License
Copyright date
01/01/2024
Distributor
Related resources
Author
D'Agati, Michael, Joseph
Contributor
Abstract

Multiferroic micro-electromechanical systems (MEMS) enable small, room temperature, low power magnetic sensing and wireless power transfer (WPT) in biomedical applications.This thesis presents the theory, design, microfabrication, and characterization of multiferroic MEMS magnetic sensors and WPT devices. Iron cobalt/silver (Fe50Co50/Ag) magnetostrictive material is coupled to piezoelectric aluminum nitride (AlN) to form a multiferroic sensor. Low frequency biomagnetic signals are upconverted around the length-extensional beam’s 7-16 MHz mechanical resonance to provide Q enhancement to the sensitivity. The up conversion exploits a nonlinear phenomenon of magnetostrictive materials with applied mechanical strain. For two devices studied, modulated sensitivities of 58.4 mA/T and 37.7 mA/T were observed along with resolutions of 5.03 nT/√Hz and 2.72 nT/√Hz over a bandwidth larger than the biomagnetic frequency spectrum (0.1Hz to 1kHz). The sensors’ sensitivity was limited by Duffing nonlinearity and the relatively low piezoelectric coefficients of AlN. To improve sensitivity, magnetoelectric sensors were fabricated using (Fe0.5Co0.5)0.92Hf0.08 coupled to 28% aluminum scandium nitride (Al0.72Sc0.28N). Increasing sensitivity improved the resolution from 5.03 nT/√Hz to 2.16 nT/√Hz. To delay the onset of thermal Duffing nonlinearity, various anchoring tether lengths were explored in Fe0.5Co0.5/Ag – AlN magnetoelectric sensors to provide better heat conduction away from the structure. Also, silicon dioxide (SiO2) was added to compensate the temperature coefficient of frequency (TCF). Larger achievable strain was verified before the onset of Duffing nonlinearity, providing increased modulation of the Fe0.5Co0.5/Ag and a resolution of 1.11 nT/√Hz, an 86% improvement when compared to a long tether device with the same layer stack (8.02 nT/√Hz) and a 78% improvement over the initial (Fe50Co50/Ag) – AlN long tether devices with no SiO2 thermal compensation. WPT measurements were taken using (Fe50Co50/Ag) – AlN magnetoelectric devices. By sending a magnetic field at the device resonance frequency, optimal WPT can be achieved. Devices were packaged with a magnetic bias circuit and the output power was measured. For a device at 7.44MHz, an output power of 126.8 nW and a power density of 1196.2 uW/mm3 is projected when measuring with both electrodes.

Advisor
Olsson III, Roy, H.
Date of degree
2024
Date Range for Data Collection (Start Date)
Date Range for Data Collection (End Date)
Digital Object Identifier
Series name and number
Volume number
Issue number
Publisher
Publisher DOI
Journal Issue
Comments
Recommended citation