  • Publication
    Computer Aided Clinical Trials for Implantable Cardiac Devices
    (2018-07-12) Jang, Kuk Jin; Weimer, James; Abbas, Houssam; Jiang, Zhihao; Liang, Jackson; Dixit, Sanjay; Mangharam, Rahul
    In this paper we aim to answer the question, ``How can modeling and simulation of physiological systems be used to evaluate life-critical implantable medical devices?'' Clinical trials for medical devices are becoming increasingly inefficient as they take several years to conduct, at very high cost and suffer from high rates of failure. For example, the Rhythm ID Goes Head-to-head Trial (RIGHT) sought to evaluate the performance of two arrhythmia discriminator algorithms for implantable cardioverter defibrillators, Vitality 2 vs. Medtronic, in terms of time-to-first inappropriate therapy, but concluded with results contrary to the initial hypothesis - after 5 years, 2,000+ patients and at considerable ethical and monetary cost. In this paper, we describe the design and performance of a computer-aided clinical trial (CACT) for Implantable Cardiac Devices where previous trial information, real patient data and closed-loop device models are effectively used to evaluate the trial with high confidence. We formulate the CACT in the context of RIGHT using a Bayesian statistical framework. We define a hierarchical model of the virtual cohort generated from a physiological model which captures the uncertainty in the parameters and allows for the systematic incorporation of information available at the design of the trial. With this formulation, the CACT estimates the inappropriate therapy rate of Vitality 2 compared to Medtronic as 33.22% vs 15.62% (p
  • Publication
    Real-time Heart Model for Implantable Cardiac Device Validation and Verification
    (2010-01-20) Jiang, Zhihao; Pajic, Miroslav; Connolly, Allison T; Dixit, Sanjay; Mangharam, Rahul
    Designing bug-free medical device software is dif- ficult, especially in complex implantable devices that may be used in unanticipated contexts. Safety recalls of pacemakers and implantable cardioverter defibrillators due to firmware problems between 1990 and 2000 affected over 200,000 devices, comprising 41% of the devices recalled and are increasing in frequency. There is currently no formal methodology or open experimental platform to validate and verify the correct operation of medical device software. To this effect, a real-time Virtual Heart Model (VHM) has been developed to model the electrophysiological operation of the functioning (i.e. during normal sinus rhythm) and malfunctioning (i.e. during arrhythmia) heart. We present a methodology to extract timing properties of the heart to construct a timed-automata model. The platform exposes functional and formal interfaces for validation and verification of implantable cardiac devices. We demonstrate the VHM is capable of generating clinically-relevant response to intrinsic (i.e. premature stimuli) and external (i.e. artificial pacemaker) signals for a variety of common arrhythmias. By connecting the VHM with a pacemaker model, we are able to pace and synchronize the heart during the onset of irregular heart rhythms. The VHM has also been implemented on a hardware platform for closed-loop experimentation with existing and virtual medical devices. The VHM allows for exploratory electrophysiology studies for physicians to evaluate their diagnosis and determine the appropriate device therapy. This integrated functional and formal device design approach will potentially help expedite medical device certification for safer operation.
  • Publication
    Computer Aided Clinical Trials for Implantable Cardiac Devices
    (2016-08-19) Abbas, Houssam; Jiang, Zhihao; Jang, Kuk Jin; Beccani, Marco; Liang, Jackson; Dixit, Sanjay; Mangharam, Rahul
    In this effort we investigate the design and use of physiological and device models to conduct pre-clinical trials to provide early insight in the design and execution of the actual clinical trial. Computer models of physiological phenomena like cardiac electrical activity can be extremely complex. However, when the purpose of the model is to interact with a medical device, then it becomes sufficient to model the measurements that the device makes, e.g. the intra-cardiac electrograms (EGMs) that an Implantable Cardioverter Defibrillator (ICD) measures. We present a probabilistic generative model of EGMs, capable of generating exemplars of various arrhythmias. The model uses deformable shape templates, or motifs, to capture the variability in EGM shapes within one EGM channel, and a cycle length parameter to capture the variability in cycle length in one EGM channel. The relation between EGM channels, which is essential for determining whether the current arrhythmia is potentially fatal, is captured by a time-delayed Markov chain, whose states model the various combinations of (learned) motifs. The heart model is minimally parameterized and is learned from real patient data. Thus the statistics of key features reflect the statistics of a real cohort, but the model can also generate rare cases and new combinations from the inferred probabilities. On the device end, algorithms for signal sensing, detection and discrimination for major ICD manufacturers have been implemented both in simulation and on hardware platforms. The generated arrhythmia episodes are used as input to both the modeled ICD algorithms and real ICDs as part of a Computer Aided Clinical Trial (CACT). In a CACT, a computer model simulates the inputs to the device (such as a new, investigational ICD), and the device’s performance is evaluated. By incorporating these results into the appropriate statistical framework, the Computer Aided Clinical Trial results can serve as regulatory evidence when planning and executing an actual clinical trial. We demonstrate this by conducting a mock trial similar to the 2005-2010 RIGHT trial which compared the discrimination algorithms from two major ICD manufacturers. The results of the CACT clearly demonstrate that the failed outcome of the RIGHT trial could have been predicted and provides statistical support for deeper results that could have been captured prior to the trial.
  • Publication
    High-Level Modeling for Computer-Aided Clinical Trials of Medical Devices
    (2016-08-16) Abbas, Houssam; Jiang, Zhihao; Jang, Kuk Jin; Beccani, Marco; Liang, Jackson; Dixit, Sanjay; Mangharam, Rahul
  • Publication
    Real-time Heart Model for Implantable Cardiac Device Validation and Verification
    (2010-07-06) Jiang, Zhihao; Pajic, Miroslav; Connolly, Allison; Dixit, Sanjay; Mangharam, Rahul
    Designing bug-free medical device software is challenging, especially in complex implantable devices that may be used in unanticipated contexts. Safety recalls of pacemakers and implantable cardioverter defibrillators due to firmware problems between 1990 and 2000 affected over 200, 000 devices. This encompasses 41% of the devices recalled and continues to increase in frequency. There is currently no formal methodology or open experimental platform to validate and verify the correct operation of medical device software. To this effect, a real-time Virtual Heart Model (VHM) has been developed to model the electrophysiological operation of the functioning (i.e. during normal sinus rhythm) and malfunctioning (i.e. during arrhythmia) heart. We present a methodology to construct a timed-automata model by extracting timing properties of the heart. The platform employs functional and formal interfaces for validation and verification of implantable cardiac devices. We demonstrate the VHM is capable of generating clinically-relevant response to intrinsic (i.e. premature stimuli) and external (i.e. artificial pacemaker) signals for a variety of common arrhythmias. By connecting the VHM with a pacemaker model, we are able to pace and synchronize the heart during the onset of irregular heart rhythms. The VHM has also been implemented on a hardware platform for closed-loop experimentation with existing and virtual medical devices. This integrated functional and formal device design approach has potential to help expedite medical device certification for safe operation.
  • Publication
    Real-time Heart Model for Implantable Cardiac Device Validation and Verification
    (2010-03-26) Jiang, Zhihao; Pajic, Miroslav; Connolly, Allison T; Dixit, Sanjay; Mangharam, Rahul
    Designing bug-free medical device software is difficult, especially in complex implantable devices that may be used in unanticipated contexts. Safety recalls of pacemakers and implantable cardioverter defibrillators due to firmware problems between 1990 and 2000 affected over 200,000 devices, comprising 41% of the devices recalled and are increasing in frequency. There is currently no formal methodology or open experimental platform to validate and verify the correct operation of medical device software. To this effect, a real-time Virtual Heart Model (VHM) has been developed to model the electrophysiological operation of the functioning (i.e. during normal sinus rhythm) and malfunctioning (i.e. during arrhythmia) heart. We present a methodology to extract timing properties of the heart to construct a timed-automata model. The platform exposes functional and formal interfaces for validation and verification of implantable cardiac devices. We demonstrate the VHM is capable of generating clinically-relevant response to intrinsic (i.e. premature stimuli) and external (i.e. artificial pacemaker) signals for a variety of common arrhythmias. By connecting the VHM with a pacemaker model, we are able to pace and synchronize the heart during the onset of irregular heart rhythms. The VHM has also been implemented on a hardware platform for closed-loop experimentation with existing and virtual medical devices. The VHM allows for exploratory electrophysiology studies for physicians to evaluate their diagnosis and determine the appropriate device therapy. This integrated functional and formal device design approach will potentially help expedite medical device certification for safer operation.